Maintenance GP/GPS 6600A
46
6.14 Electrical Schematic (CAN models only)
Ref. Description Ref. Description
A Generator C Engine
B Control box D Electric start engines
Ref. Description Ref. Description
1 Main stator winding 1 12 Engine ON / OFF switch
2 Main stator winding 2 13 Rectifier
3 Auto idle unit 14 Rotor winding/brushes
4 Main circuit breaker 15 Secondary (excitation) winding
5 Voltage selector switch
(120V/240V position shown)
16 DC winding
6 GFI duplex receptacle—120V 17 Automatic voltage regulator (AVR)
7 Twist-lock receptacle—120V 18 15A fuse (GPS only)
8 Twist-lock receptacle—120/240V 19 Ignition switch (GPS only)
9 Auto idle switch 21 20A circuit breaker
10 5A fuse 22 20A circuit breaker
(GP 3800 CAN only)
11 Capacitor 23 30A circuit breaker
(GP 5600/6600 CAN only)