Wacker Neuson GP 6600A Betreibershandbuch

Stöbern Sie online oder laden Sie Betreibershandbuch nach Stromgeneratoren Wacker Neuson GP 6600A herunter. Wacker Neuson GP 6600A Operator`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - GPS 6600A

www.wackergroup.comGeneratorGP 6600AGPS 6600AOPERATOR’S MANUAL0160534en 00301070160534EN

Seite 2 - CARBON MONOXIDE

Safety Information GP/GPS 6600A103.2.12 ALWAYS store the equipment properly when it is not being used.Equipment should be stored in a clean, dry locat

Seite 3

GP/GPS 6600A Safety Information113.3 Operator Safety while using Internal Combustion EnginesInternal combustion engines present special hazards during

Seite 4 - 6. Maintenance 36

Safety Information GP/GPS 6600A123.4 Service SafetyPoorly maintained equipment can become a safety hazard! In orderfor the equipment to operate safel

Seite 5 - 1. Foreword

GP/GPS 6600A Safety Information133.5 Label Locations GND88897

Seite 6

Safety Information GP/GPS 6600A143.6 Safety and Operating LabelsWacker machines use international pictorial labels where needed.These labels are descr

Seite 7

GP/GPS 6600A Safety Information15Press circuit breaker switch to OFF position.Check the fuel level.Open the fuel flow valve.Press engine switch to ON

Seite 8 - 3. Safety Information

Safety Information GP/GPS 6600A16Close the fuel flow valve.DANGER! Asphyxiation hazard. Read the operator’s manual for instructions.Use in a well-vent

Seite 9 - 3.2 Operating Safety

GP/GPS 6600A Safety Information17Important Emissions InformationThis equipment meets California EVP emission regulations for small off-road engines.Th

Seite 10

Technical Data GP/GPS 6600A184. Technical Data4.1 GeneratorItem No. GP 6600A0620014GP 6600A0620015GPS 6600A0620016GeneratorMaximum OutputW6600Continuo

Seite 11

GP/GPS 6600A Technical Data19Item No. GP 6600A CAN0620045GP 6600A CAN0620046GPS 6600A CAN0620047GeneratorMaximum OutputW6600Continuous OutputW5500Type

Seite 12 - 3.4 Service Safety

DANGERCARBON MONOXIDEUsing a generator indoors CAN KILL YOU IN MINUTES.Generator exhaust contains carbon

Seite 13 - 3.5 Label Locations

Technical Data GP/GPS 6600A204.2 EngineItem No. GP 6600A06200140620015GP 6600ACAN06200450620046GPS 6600A0620016GPS 6600ACAN0620047EngineEngine Type Si

Seite 14

GP/GPS 6600A Operation215. Operation5.1 Determining Power RequirementsThis generator is designed to operate single-phase, 60 Hz appliancesrunning at 1

Seite 15

Operation GP/GPS 6600A225.2 Outdoor InstallationPlace the generator in an area where it will not be exposed to rain,snow, or direct sunlight. Make sur

Seite 16

GP/GPS 6600A Operation235.5 Battery Installation (GPS only)See Graphic: wc_gr0027015.5.1 Align the holes found in the battery tray (a) to the holes on

Seite 17

Operation GP/GPS 6600A245.6 Wheel KitSee Graphic: wc_gr002658The wheel kit (Part No. 0161308) is a standard item on Item Number0620012, 0620015, 06200

Seite 19 - GP/GPS 6600A Technical Data

Operation GP/GPS 6600A265.7 Generator DeratingAll generators are subject to derating for altitude and temperature.Internal combustion engines, unless

Seite 20

GP/GPS 6600A Operation275.8 Grounding the GeneratorSee Graphic: wc_gr000544A ground connection (a) is located on the generator frame. For properoperat

Seite 21 - GP/GPS 6600A Operation

Operation GP/GPS 6600A285.10 Use of Extension CordsWhen a long extension cord is used to connect an appliance or tool tothe generator, a voltage loss

Seite 22 - Operation GP/GPS 6600A

GP/GPS 6600A Operation295.11 Control PanelSee Graphic: wc_gr002498Ref. Description Ref. Descriptiona Engine Switch g GFI test buttonb Auto Idle Switch

Seite 23

GP/GPS 6600A Table of Contents31. Foreword 52. California Evaporative Emission Control Warranty Statement 63. Safety Information 83.1 Laws Pertaining

Seite 24

Operation GP/GPS 6600A305.12 Ground Fault Interrupt (GFI)See Graphic: wc_gr002498The two receptacles (f) are protected by a ground fault circuit inter

Seite 25

GP/GPS 6600A Operation315.14 Engine Auto IdleSee Graphic: wc_gr002498The auto idle switch (b) automatically reduces engine speedapproximately 7 second

Seite 26

Operation GP/GPS 6600A325.16 Voltage SelectionSee Graphic: wc_gr002497The voltage selector switch (e) allows the generator to operate in eithersingle

Seite 27

GP/GPS 6600A Operation335.17 Before Starting5.17.1 Read and understand the safety and operating labels and instructionsat the beginning of this manual

Seite 28

Operation GP/GPS 6600A345.18 To StartSee Graphic: wc_gr002500Before starting, be sure you read and understand all the safety andoperating instructions

Seite 29

GP/GPS 6600A Operation355.19 To StopSee Graphic: wc_gr0025005.19.1 Turn off and disconnect all tools and appliances attached to thegenerator.5.19.2 Pl

Seite 30

Maintenance GP/GPS 6600A366. Maintenance6.1 Engine MaintenanceThe chart below lists basic machine and engine maintenance. Refer tothe engine manufactu

Seite 31

GP/GPS 6600A Maintenance376.3 Engine OilSee Graphic: wc_gr0000226.3.1 Drain the oil while the engine is still warm.6.3.2 Remove the oil filler plug (a

Seite 32

Maintenance GP/GPS 6600A386.4 Servicing Air CleanerSee Graphic: wc_gr002815Service the air cleaner frequently to prevent carburetor malfunction. NOTIC

Seite 33

GP/GPS 6600A Maintenance396.5 Spark PlugSee Graphic: wc_gr000028Clean or replace the spark plug as needed to ensure proper operation.Refer to the engi

Seite 34

Table of Contents GP/GPS 6600Awc_bo0160534en_003TOC.fm 46. Maintenance 366.1 Engine Maintenance ...

Seite 35

Maintenance GP/GPS 6600A406.6 Cleaning the Sediment CupSee Graphic: wc_gr0000296.6.1 Turn the fuel valve off. 6.6.2 Remove the sediment cup (a) and th

Seite 36 - Maintenance GP/GPS 6600A

GP/GPS 6600A Maintenance416.8 Adjusting Engine SpeedSee Graphic: wc_gr000032Generators require a fixed engine speed to maintain the correctvoltage. En

Seite 37 - GP/GPS 6600A Maintenance

Maintenance GP/GPS 6600A426.9 StorageBefore storing the generator for a long period of time:6.9.1 Close the fuel valve and remove and empty the sedime

Seite 38

GP/GPS 6600A Maintenance436.11 Troubleshooting 6.12 Wire ColorsProblem / Symptom Reason / RemedyIf engine doesn't start, check that:• Engine swit

Seite 39

Maintenance GP/GPS 6600A446.13 Electrical Schematic Ref. Description Ref. DescriptionA Generator C EngineB Control box D Electric start enginesRef.

Seite 40

GP/GPS 6600A Maintenance45

Seite 41

Maintenance GP/GPS 6600A466.14 Electrical Schematic (CAN models only) Ref. Description Ref. DescriptionA Generator C EngineB Control box D Electric st

Seite 42

GP/GPS 6600A Maintenance47

Seite 43

Maintenance GP/GPS 6600A486.15 Engine SchematicSee Graphic: wc_gr002580 Ref. Description Ref. DescriptionA Generator D Wacker EngineB Control box E H

Seite 44

GP/GPS 6600A Maintenance49

Seite 45

5CALIFORNIAProposition 65 Warning: Engine exhaust, some of its constituents, and certain vehiclecomponents, contain or emit chemicals known to the St

Seite 46

Maintenance GP/GPS 6600A50Notes

Seite 48

Wacker Construction Equipment AG · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02 - 0 · Fax:

Seite 49

California Evaporative Emission Control Warranty Statement62. California Evaporative Emission Control Warranty StatementYOUR WARRANTY RIGHTS AND OBLI

Seite 50

California Evaporative Emission Control Warranty Statement7OWNER’S WARRANTY RESPONSIBILITIES:As the portable generator owner, you are responsible for

Seite 51

Safety Information GP/GPS 6600A83. Safety InformationThis manual contains DANGER, WARNING, CAUTION, NOTICE andNOTE callouts which must be followed to

Seite 52

GP/GPS 6600A Safety Information93.2 Operating SafetyBACKFEED FROM THE GENERATOR INTO THE PUBLIC POWERDISTRIBUTION SYSTEM CAN CAUSE SERIOUS INJURY ORDE

Kommentare zu diesen Handbüchern

Keine Kommentare