Seitenansicht 40
GP/GPS 6600A Maintenance
41
6.8 Adjusting Engine Speed
See Graphic: wc_gr000032
Generators require a fixed engine speed to maintain the correct
voltage. Engine speed is controlled by a governor which automatically
adjusts to varying loads on the engine to maintain a constant speed.
There is no throttle control.
To set the engine to the proper speed:
Turn the speed adjusting screw (b) in or out to obtain a no-load speed.
See Technical Data.
NOTICE: Setting the engine speed too high or too low may damage
tools and other appliances attached to the generator.