GeneratorGV 7000AGV 7003AOPERATOR’S MANUAL0157387en 00609080157387EN
Safety Information GV 7000A / 7003Awc_si000108gb.fm 102.4 Label Locationswc_gr001298PETROLGASOLINAISSINCIBENZINCALDO !HEISS !HOT !CHAUD ! DANG
GV 7000A / 7003A Safety Informationwc_si000108gb.fm 112.5 Safety and Operating LabelsWacker Neuson machines use international pictorial labels wherene
Safety Information GV 7000A / 7003Awc_si000108gb.fm 12DANGER! Asphyxiation hazard. Read the Operator’s Manual for instructions.DANGER!No sparks, flame
GV 7000A/7003A Operationwc_tx000273gb.fm 133. Operation3.1 Determining Power RequirementsWacker Neuson generator Model GV 7000A is designed to operate
Operation GV 7000A/7003Awc_tx000273gb.fm 14Approximate Starting Power Requirements• Incandescent lights and appliances such as irons and hot plates, w
GV 7000A/7003A Operationwc_tx000273gb.fm 153.2 InstallationPlace the generator in an area where it will not be exposed to rain,snow, or direct sunligh
Operation GV 7000A/7003Awc_tx000273gb.fm 163.3 Generator DeratingAll generators are subject to derating for altitude and temperature.Internal combusti
GV 7000A/7003A Operationwc_tx000273gb.fm 173.4 Use of Extension CordsWhen a long extension cord is used to connect an appliance or tool tothe generato
Operation GV 7000A/7003Awc_tx000273gb.fm 18Minimum Extension Cord Size Chart Minimum Extension Cord Size Graph Minimum Extension Cord Size230V/1
GV 7000A/7003A Operationwc_tx000273gb.fm 193.5 Grounding the GeneratorThe neutral of this machine is not connected to ground. Understandard operating
DANGERCARBON MONOXIDEUsing a generator indoors CAN KILL YOU IN MINUTES.Generator exhaust contains carbon
Operation GV 7000A/7003Awc_tx000273gb.fm 203.7 Control PanelSee graphic: wc_gr001275 and wc_gr001369The circuit breaker protects the generator from se
GV 7000A/7003A Operationwc_tx000273gb.fm 21 Ref. Description Ref. Descriptione Main circuit breaker -10 A, 12 A, 10 A 3-Polef1 Schuko IP54 (CEE 7) rec
Operation GV 7000A/7003Awc_tx000273gb.fm 223.8 Before Starting3.8.1 Read and understand safety and operating instructions at beginning ofthis manual.
GV 7000A/7003A Operationwc_tx000273gb.fm 233.9 To StartSee Graphic: wc_gr0012993.9.1 Disconnect all loads from the generator and place main circuit br
Maintenance GV 7000A/7003Awc_tx000274gb.fm 244. Maintenance4.1 Engine MaintenanceThe chart below lists basic machine and engine maintenance. Refer toy
GV 7000A/7003A Maintenancewc_tx000274gb.fm 254.3 Engine OilSee Graphic: wc_gr0000224.3.1 Drain the oil while the engine is still warm.4.3.2 Remove the
Maintenance GV 7000A/7003Awc_tx000274gb.fm 264.4 Air CleanerSee Graphic: wc_gr0001287The engine is equipped with a single element air cleaner. Service
GV 7000A/7003A Maintenancewc_tx000274gb.fm 274.5 Spark PlugSee Graphic: wc_gr000028Clean or replace the spark plug as needed to ensure proper operatio
Maintenance GV 7000A/7003Awc_tx000274gb.fm 284.6 Engine SpeedSee Graphic: wc_gr001300Generators require a fixed engine speed to maintain the correctvo
GV 7000A/7003A Maintenancewc_tx000274gb.fm 294.7 StorageBefore storing the generator for a long period of time:4.7.1 Close the fuel valve and remove a
GV 7000A/7003A Table of Contentswc_bo0157387en_006TOC.fm 31. Foreword 52. Safety Information 62.1 Operating Safety ...
Maintenance GV 7000A/7003Awc_tx000274gb.fm 304.9 Troubleshooting Problem / Symptom Reason / RemedyIf engine doesn't start, check that:• Engine
GV 7000A/7003A Maintenancewc_tx000274gb.fm 314.10 Electrical Schematic—GV 7000ASee Graphic: wc_gr001302 Ref. Description Ref. Description1 Main Wi
Maintenance GV 7000A/7003Awc_tx000274gb.fm 324.11 Electrical Schematic—GV 7003ASee Graphic: wc_gr001249 Notes Ref. Description Ref. Description1 Ma
GV 7000A/7003A Technical Datawc_td000107gb.fm 335. Technical Data5.1 GeneratorItem No. 0009348 0009353 0009358 0009363GV 7000A GeneratorMaximum Output
Technical Data GV 7000A/7003Awc_td000107gb.fm 34Item No. 0009349 0009354 0009359 0009364GV 7003A GeneratorMaximum OutputkVA7.45Continuous OutputkVA7.1
GV 7000A/7003A Technical Datawc_td000107gb.fm 355.2 EngineEngine Power RatingNet power rating per SAE J1349. Actual power output may vary due tocondit
2008-Value_Gen_GV7000A_Q.fmWilliam Lahner Dan DomanskiVice President of Engineerin
2008-Value_Gen_GV7003A_Q.fmWilliam Lahner Dan DomanskiVice President of Engineerin
Table of Contents GV 7000A/7003Awc_bo0157387en_006TOC.fm 45. Technical Data 335.1 Generator ...
Wacker Construction Equipment AG · Preußenstraße 41 · D-80809 München · Tel.: +49-(0)89-3 54 02 - 0 · Fax:
Forewordwc_si000108gb.fm 51. ForewordThis manual provides information and procedures to safely operateand maintain this Wacker Neuson model. For your
Safety Information GV 7000A / 7003Awc_si000108gb.fm 62. Safety InformationThis manual contains DANGER, WARNING, CAUTION, NOTICE andNOTE callouts which
GV 7000A / 7003A Safety Informationwc_si000108gb.fm 72.1 Operating SafetyBACKFEED FROM THE GENERATOR INTO THE PUBLIC POWERDISTRIBUTION SYSTEM CAN CAUS
Safety Information GV 7000A / 7003Awc_si000108gb.fm 82.1.10 ALWAYS be sure the machine is on a firm, level surface and will nottip, roll, slide, or fa
GV 7000A / 7003A Safety Informationwc_si000108gb.fm 92.3 Service SafetyPoorly maintained equipment can become a safety hazard! In orderfor the equipm
Kommentare zu diesen Handbüchern