2.14 Before Starting
2.14.1 Read and understand the safety and operating labels and instructions
at the beginning of this manual.
2.14.2 Inspect the generator for any signs of damage which may affect
operation or pose a safety hazard.
2.14.3 Check:
oil level in engine
fuel level
condition of air cleaner
tightness of external fasteners
condition of fuel lines.
Note: The engine is equipped with an oil alert system. If the oil level in
the engine drops too low, the engine will not start.
2.14.4 Fill the fuel tank with fresh, regular, unleaded grade gasoline. DO NOT
use an oil/gas mixture. The use of gasohol or any fuel containing more
than 10% ethanol is not recommended. Consult the engine owner's
manual for complete fuel specifications.
NOTICE: Fill the tank after placing the machine on level ground.