Operation GP 3800A
32
5.16 To Start
See Graphic: wc_gr002499
Before starting, be sure you read and understand all the safety and
operating instructions in this manual.
5.16.1 Disconnect all loads from the generator and place the main breaker in
the "OFF" position (a2).
5.16.2 Set the Auto Idle Switch (c) to "OFF".
5.16.3 Open the fuel valve (d1).
Note: If the engine is cold, move the choke lever to the closed position
(e2). If the engine is hot, set the choke to the open position (e1).
5.16.4 Turn the engine switch to "ON" (b1).
5.16.5 Pull the starter rope (f).
Note: If the oil level in the engine is low, the engine will not start. If this
happens, check the oil level and add oil as needed.
5.16.6 As the engine warms up, move the choke lever to the OPEN position
(e1).
5.16.7 Allow the engine to warm up for a few minutes before placing the main
breaker in the "ON" position (a1) and attaching loads.