Wacker Neuson EHB 10 series Betreibershandbuch Seite 44

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 43
Troubleshooting EHB 11
44
9 Troubleshooting
Potential faults, their causes and remedies can be found in the following table.
Malfunction Cause Remedy
Machine not in operation For machines with 230 V:
Input voltage too high (> 300 V)
or too low (< 80 V).
Provide correct voltage; if nec-
essary use an extension cable
with sufficient cross section.
For machines with 115 V:
Input voltage too high (> 150 V)
or too low (< 45 V).
Provide correct voltage; if nec-
essary use an extension cable
with sufficient cross section.
Inverter has switched off due to
excess temperature.
Let machine cool off.
Power cable interrupted. Check power cable, have it re-
placed if defective. *
* Have these tasks carried out by the service department of your Wacker Neuson contact person.
Blocked percussion system High grease resistance due to
very low temperatures.
Allow machine to warm up in
warm environment (e.g. heated
rooms).
Seizing of moving parts (e.g.
due to prolonged dry running).
Have defective components re-
placed. *
Drill is stuck/jammed Too much borer dust in bore-
hole.
Pull drill bit out off borehole and
remove dust from drill bit.
Interfering reinforcing steel. Redrill borehole.
Seitenansicht 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 59 60

Kommentare zu diesen Handbüchern

Keine Kommentare