Operation CRT 48-31V-ES
wc_tx000143gb.fm 20
4.4 Before Starting
Before starting the trowel, check the following:
fuel level
oil level in the engine
condition of the air filter
condition of trowel arms and blades
Grease the trowel arms daily.
4.5 Starting
Before starting the operator must know the location and function of all
controls.
4.5.1 Push down on the throttle foot pedal, turn the engine keyswitch (s),
and hold it until the engine starts.
Note: If the engine is cold, pull out the choke control knob fully.
NOTICE: Cranking the engine for more than 5 seconds can cause
starter damage. If the engine fails to start, release the keyswitch and
wait 10 seconds before operating the starter again.
Note: The engine has an oil alert switch designed to stop the engine
automatically if the oil level gets too low. If engine will not start, or stops
during operation, check engine oil level.
4.5.2 Allow the engine to warm up before operating the trowel.
4.6 Stopping
To stop trowel movement, return joystick(s) or control levers to their
neutral position and release pressure on the throttle foot pedal.
To stop the engine, turn the keyswitch to “O” (off).